Abstract
The Bone Tumour X-ray Radiograph Dataset (BTXRD) is one of the first large open radiograph benchmarks for bone-tumour research, and its clinical metadata are an obvious input for multimodal classifiers. We show that one of those fields, anatomical site, is recorded only for tumour images: its union is the label itself (aggregate univariate AUC 1.000, whereas no single site column exceeds 0.67), and a gradient-boosted model given the site labels reaches AUC 0.99–1.00 from metadata alone. A per-column leakage screen misses this; an aggregate-group screen catches it. After removing the leak we report a leakage-audited baseline for normal-versus-tumour detection on all 3,746 images (21 exact duplicates removed) under a pseudo-patient grouped split, a proxy for patient-level partitioning since BTXRD has no patient identifier. Forty-three radiomic features with gradient-boosted trees were compared with ResNet-18, EfficientNet-B0 and a soft-voting ensemble across three grouped seeds and one image-level seed, with bootstrap intervals, paired AUC differences and Holm-corrected McNemar tests. EfficientNet-B0 was the strongest model (grouped AUC 0.875 ± 0.025, range 0.850–0.901; image-level 0.915), exceeding the radiomics-plus-metadata model by 0.049–0.075 AUC in every run. The audited metadata (age, sex, region, view) alone reached 0.666 ± 0.013 and added at most 0.04 AUC to radiomics, inconsistently across seeds; the ensemble added no more than 0.025 over its best member; the acquisition source contributed 0.01–0.02. Image-level splitting inflated every model relative to grouped splitting, by 0.02–0.04 for image models and 0.065 for metadata alone. Grad-CAM maxima of EfficientNet-B0 fell inside expert lesion masks in one image in four (chance 3%). The between-seed variation in AUC (SD 0.01–0.04) exceeded most model-to-model differences, so we report ranges rather than single values. Pipeline, results files and per-image predictions are released. Because the grouping is a proxy and not verified patient identity, the baseline is leakage-reduced rather than leakage-free; it is a methodological baseline, not a clinically validated tool.
Keywords: Bone tumour, radiography, data leakage, benchmark, reproducibility, convolutional neural network, radiomics, confounding